ElementFaçade 7 Structural Glazed
Technical informationPerformance
Comfort
- Air tightness
- AE1200 (1200Pa)
- Water tightness
- RE1200 (1200Pa)
- Wind load resistance
- 2400 Pa
- CWCT tested according to
- Sequence B
- Air Leakage CWCT
- A4 (600Pa)
- Water Penetration CWCT
- R7 (600Pa)
- Wind Resistance (Serviceability) CWCT
- 2400 Pa
- Wind Resistance (Safety) CWCT
- 3600 Pa
Properties
Max. dimensions & weight
- Min. intertia mullion - Ix
- 192 cm4
- Max. intertia mullion - Ix
- 453 cm4
- Min. intertia transom - Ix
- 188 cm4
- Max. intertia transom - Ix
- 506 cm4
- Max. intertia transom - Iy (glass load)
- 712 cm4
Sightlines
- Min. width T-profile
- 75 mm
- Min. visible width (interior view)
- 75 mm
- Min. visible width (exterior view)
- 11 mm
- Min. depth mullion
- 136.5 mm
- Min. depth transom
- 136.5 mm
Glazing
- Glazing method
- Structural Glued Glazing